Roland MC-4 Manuel du propriétaire Page 121

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 180
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 120
121
Sample Edit
Sampling
Edit Time Stretch
This operation stretches or shrinks the sample to modify the length
or tempo.
You can stretch or shrink the sample by a factor of one half to double
the original length.
1.
Press [TIME STRETCH].
Alternatively, hold down [SHIFT] and press [F4 (Time Stretch)].
2.
Press [F1 (Sample List)] and select a sample.
3.
Press [CURSOR (up/down)] to select how you want
to specify the tempo/length.
4.
Use [VALUE] or [INC/DEC] to specify the tempo/
length.
5.
Press [F6 (Execute)].
The length of the sample will be changed as specified.
* To cancel, press [F5 (Close)].
Normalize
This operation raises the level of the entire sample as much as
possible without exceeding the maximum level.
1.
Press [NORMALIZE/AMP].
2.
Press [F1 (Sample List)] and select a sample.
3.
If you want to replace the current sample with the
normalized sample, press [F4 (Over Write)] to display
the “
” symbol.
4.
Press [F6 (Execute)].
A message will ask you for confirmation.
5.
To execute, press [F6 (Execute)].
* To cancel, press [F5 (Cancel)].
Edit
Time
Stretch
BPM:
Change the BPM (p. 116) of the sample to the BPM
you specify.
Time:
Specify the length of the sample as a time value.
Rate:
Specify the length relative to the current length of
the sample.
Range:
50.0–200.0%
Type TYPE01–
TYPE10
Lower settings of this value will make
the sound more suitable for faster phras-
es, and higher settings will make the
sound more suitable for slower phrases.
Quality
Adjust
1–10 Make fine adjustments to the tonal qual-
ity of the Time Stretch.