System Mode (Settings Common to All Modes)
fig.08-05.eps_50
MIDI
Parameter
Value Description
Device ID (Device ID Number)
17–32
When you want to transmit or receive System Exclusive messages, set this pa-
rameter to match the Device ID number of the other MIDI device.
Clock Source
INT
The LFO frequency or Tone-FX change will synchronize to the patch tempo.
MIDI The LFO frequency or Tone-FX change will synchronize to the external MIDI
clock.
USB MIDI The LFO frequency or Tone-FX change will synchronize to the external USB
MIDI clock.
Receive MIDI Ch
(Receive MIDI Channel)
1–16
Specifies the MIDI receive channel.
Receive Sw
OFF, ON
Specifies whether MIDI messages will be received (ON) or not received
(OFF).
Program Change
(Receive Program Change Switch)
OFF, ON
Specifies whether Program Change messages will be received (ON) or not
(OFF).
Bank Select
(Receive Bank Select Switch)
OFF, ON
Specifies whether Bank Select messages will be received (ON) or not (OFF).
System Ex
(Receive System Exclusive Switch)
OFF, ON
Specifies whether System Exclusive messages will be received (ON) or not
(OFF).
Transmit MIDI Ch
(Transmit MIDI Channel)
1–16, RX CH,
OFF
Specifies the transmit channel of MIDI messages.
If you do not want to transmit MIDI messages to external MIDI devices, turn
this parameter “OFF.” If you want the transmit channel to always match the
Receive MIDI Channel, set this parameter to “RX CH.”
Program Change
(Transmit Program Change
Switch)
OFF, ON
Specifies whether Program Change messages will be transmitted (ON) or not
(OFF).
Bank Select
(Transmit Bank Select Switch)
OFF, ON
Specifies whether Bank Select messages will be transmitted (ON) or not
(OFF).
Active Sens
(Transmit Active Sensing Switch)
OFF, ON
Specifies whether Active Sensing messages will be transmitted (ON) or not
(OFF).
Edit Data
(Transmit Edit Data Switch)
OFF, ON
Specify whether changes you make in the settings of a patch will be transmit-
ted as system exclusive messages (ON), or will not be transmitted (OFF).
Clock Out
OFF, ON
Specifies whether MIDI clock will be transmitted (ON) or not (OFF).
V-Synth-GT_e.book 198 ページ 2007年4月9日 月曜日 午後1時46分