Roland R-1000 Manuel de service Page 15

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 136
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 14
Manual
Double Sheet Detector R1000 series E20
B0046991 / Rev. 1.6
Technical data
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
15
2.3.2 Sensor P42AGS
P42AGS P42AGS P42AGS
with straight cable plug with 90° angled cable plug
All dimensions are in mm. Length tolerance ± 0.8 mm, all other dimensions ± 0.2 mm
Fig. 3: Sensor P42AGS
Technical data
Measuring range
2)
: 0.2 – 4.0 mm .01 - .16 inch
Ambient temperature: 0 – 60 °C 30 – 140 °F
Class of protection: IP65
Weight: ca. 0.42 kg 0.93 lbs
Sensor cable: pluggable
1)
Necessary space for sensor plug connection
2)
Related to single sheet thickness
Pos: 14 /Doppel blech/Sensor en/P-Sensoren/P 75/P75VGS Te chn. Daten @ 0 \mod_1138 636403405_501 .doc @ 1248 @ 3 @ 1