Manual
Double Sheet Detector R1000 series E20
Start-up
B0046991 / Rev. 1.6
112
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
System parameter 11: Specifying the number of connected sensors (only for 4P unit).
Fig.. 64: Specifying the number of sensors
Possible choices:
1 sensor
2 sensors
3 sensors
4 sensors
Attention Changing the adjusted configuration will delete all stored program
parameters. Then the nominal thicknesses must be re-entered and
Teach-in must be performed for all sheet types!
System parameter 12: Specifying the type of actuating the sensors (only for 4P control unit).
Fig.. 65: Sensor selection
Possible choices:
External: Switching of sensor is accomplished via the external PLC cables
„Sensor selection“ A and B.
Advantage: faster sensor switching procedure.
Program: Switching of sensor is accomplished via program selection.
A sensor is assigned to each program.
Advantage: less programming effort.
system param. 11
number sensors:1
system param. 12
sel.sensor: ext.