Editing FUNCTION settings
22
r
FR-1 V-Accordion
Parameters
In the following, the messages at the right edge of the
gray bars have the following meaning:
“OK”: Can be saved in the Global area (common to all Sets).
“POW”: Reset when you switch off the FR-1.
Note: The small dot “•” means “factory setting”.
This parameter allows you to change the FR-1’s overall tuning.
The factory default, “440”, represents the reference pitch used by
all electronic musical instruments. The settings you can select
with the registers are:
This parameter allows you to choose the system used for detun-
ing the 8’ reeds of the selected register. The settings you can
select with the registers are:
This parameter allows you to transpose all sections of the FR-1, so
as to play in one key and sound in another. The settings you can
select with the registers are:
This parameter is used to set the balance between the Treble and
Bass sections. When you press register [1], the Treble section is
inaudible, while pressing register [4] means that the Bass and
Chord section is no longer audible. The settings you can select
with the registers are:
These parameters allow you to set the level of the ORCHESTRA,
BASS or CHORD orchestral sound, or of the DRUMS function for a
better balance with the other available sections. The settings you
can select with the registers are (for all parameters):
The value “0” means that the factory-set balance setting is used.
This parameter allows you to set the metronome tempo. The set-
tings you can select with the registers are:
This parameter allows you to set the metronome’s time signature.
The settings you can select are:
This parameter allows you to change the metronome’s level when
it is too loud or too soft. See page 17 for details.
This parameter allows you to set the volume of the reverb effect
with respect to the accordion and/or orchestral sounds. It applies
to all sections that are currently switched on. The settings you
can select with the registers are:
This parameter allows you to specify what kind of effect the
Reverb processor should generate. The available options are:
Master Tune [B1]/[1]
OK
415~440~466 (Hz)
Default setting: 440
1 415 3 448
2• 440 4 466
Musette Detune [C2]/[2]
OK
Dry, Classic, F-Folk, American L,
American H, Nord Eur, German L,
D-Folk L, Italian L, German H,
Alpine, Italian H, D-Folk H, French,
Scottish
Default setting: Classic
Musette Detune
1• Classic 3 Italian L
2 Nord Eur 4 French
Transpose [C
#
2]/[3]
POW
–6~0~5
Default setting: 0
Transpose
1 –5 (G) 3 +2 (D)
2• 0 (C2) 4 +4 (E)
Treble/Bass & Chord Balance [D2]/[4]
POW
b1~63,0, t1~63
Default setting: 0
1 Bass & Chord 60 3 Treble 30
2• Equal balance 4 Treble 60
Orchestra/Organ Level
Drums Sound Level
Orchestra Bass Level
Orchestra Chord Level
[E
b
2]/[5]
[E2]/[6]
[F2]/[7]
[F
#
2]/[8]
OK
OK
OK
OK
–40~Std~40
Default setting: Std
1 –40 3 +20
2• 0 4 +40
Metronome Tempo [G2]/[9]
OK
20~250
Default setting: 120
1 Adagio (72 BPM) 3 Allegro (144 BPM)
2• Moderato (120 BPM) 4 Presto (192 BPM)
Metronome Time Signature [G
#
2]/[10]
OK
1/4, 2/4, 3/4, 4/4, 5/4, 6/4, 6/8, 9/8
Default setting: 4/4
12/434/4
23/446/8
Metronome Level [A2]/[11]
OK
Off, Low, Medium, High
Default setting: Medium
1 Off 3• Medium
2 Low 4 High
Reverb Level [B
b
2]/[12]
OK
0~127
Default setting: 48
10 (no reverb) 3 96
2• 48 4 127
Reverb Type [B2]/[13]
OK
Room 1~3, Hall 1~2, Plate, Delay,
Panning Dly
Default setting: Plate
Room1 [1]
Room2
Room3
These effects simulate the reverberation of a
room. They provide a well-defined spacious
reverberation.
Hall1 [2]
Hall2
These types simulate the reverberation of a
concert hall with a deeper reverberation than
the Room reverbs.
Vue de la page 21