GX-24 Control Panel Flow Chart 8/18/2009 GX-24 Control Panel Flow ChartVisual Representation of the GX-24 Control Panel This guide is a v
SELECT SHEETMenu Description FORCE Stored in MemoryYesFactory Default50 gf Setting Range30 to 250 gf (10 gf steps) Description Sets the blade force us
OFFSETMenu Description OFFSET Stored in MemoryYesFactory Default0.250 mmSetting Range0.000 to 1.000 mm (0.025 mm steps) Description Sets the amount of
ROTATEMenu Description ROTATE Stored in MemoryYesFactory Default0degSelection Choices0deg or 90deg Description Sets the direction of the coordinate ax
UPSPEEDMenu Description UPSPEED Stored in MemoryYesFactory DefaultAUTOSetting Range10 to 50 cm/s (10 cm/s steps) or AUTO Description Sets the speed fo
SAVEMenu Description SAVE Stored in MemoryYesFactory DefaultUSER1Selection ChoicesUSER1, USER2, USER3, or USER4 Description Stores the setting values
LOADMenu Description LOAD Stored in MemoryYesFactory DefaultUSER1Selection ChoicesUSER1, USER2, USER3, or USER4 Description Calls up the setting value
SMOOTHINGMenu Description SMOOTHING Stored in MemoryYesFactory DefaultONSelection ChoicesON or OFF Description • ON Cuts curves such as arcs smoothl
LANG.Menu Description LANG. Stored in MemoryYesFactory DefaultENGLISHSelection ChoicesENGLISH, , PORTOG, ITAL, ESPAN, FRANC, or DEUT Description Sele
UNITMenu Description UNIT Stored in MemoryYesFactory DefaultmmSelection Choicesmm or inch Description Selects the unit of measurement for numerical va
FACTORYDEFAULTMenu Description FACTORYDEFAULTDescription Resets the display menu values to the same settings as their factory defaults. However, the s
Menu Flow Chart Menu Flow Chart To view the description of each menu, click the corresponding menu in the figure. The description of each menu is giv
I/OMenu Description I/O Stored in MemoryYesFactory DefaultAUTOSelection ChoicesAUTO, USB, or SERIAL Description Specifies the type of interface for co
BAUDMenu Description BAUD Stored in MemoryYesFactory Default9600Selection Choices4800 or 9600 Description Sets the communication speed for a serial co
DATAMenu Description DATA Stored in MemoryYesFactory Default8 Selection Choices8 or 7 Description Sets the number of data bits for a serial connection
STOPMenu Description STOP Stored in MemoryYesFactory Default1Selection Choices1 or 2 Description Sets the number of stop bits for a serial connection.
PARITYMenu Description PARITY Stored in MemoryYesFactory DefaultNONESelection ChoicesNONE, EVEN, or ODD Description Sets the type of parity checking
HANDMenu Description HAND. Stored in MemoryYesFactory DefaultH-WIRESelection ChoicesH-WIRE or XONOFF Description Sets the handshaking (flow control) f
SELF TESTMenu Description SELF TEST Description Executes a self test to check the status of the GX-24. Use this to check the GX-24 when it appears to
REPLOTMenu Description REPLOT Stored in MemoryNoSelection ChoicesSTART or CLEAR Description • START Performs cutting using the data in the replot buf
LENGTHMenu Description MANUAL START Description Starts the reading of crop marks. This can be executed only when CROPMARK is set to MANUAL.
LENGTHMenu Description LENGTH Stored in MemoryYesFactory Default210 mmSetting Range50 to 500 mm (1 mm steps) Description Sets the distance between the
Menu Flow Chart Menu Flow Chart Display Menu
WIDTHMenu Description WIDTH Stored in MemoryYesFactory Default170 mmSetting Range50 to 610 mm (1 mm steps) Description Sets the distance between the c
BASE YMenu Description BASE Y Stored in MemoryYesFactory Default5.0 mmSetting Range0.0 to 50.0 mm (0.1 mm steps) Description Specifies the distance in
BASE XMenu Description BASE X Stored in MemoryYesFactory Default5.0 mmSetting Range0.0 to 50.0 mm (0.1 mm steps) Description Specifies the distance in
CROPMARKMenu Description CROPMARK Stored in MemoryYesFactory DefaultAUTOSelection ChoicesAUTO or MANUAL Description Sets the method for reading crop m
Menu Flow Chart [Back/Next]
Menu Flow Chart Menu Flow Chart Cutting Force Setup Menu Origin Setup Menu Pause Menu Language Selection Menu
SELECT SHEETMenu Description SELECT SHEET Stored in MemoryNoFactory DefaultROLLSelection ChoicesROLL, PIECE, or EDGE Description • ROLL Performs cutt
UNSETUPMenu Description UNSETUP Stored in MemoryNo Description Releases the setup condition when executed.
AREAMenu Description AREA Stored in MemoryYesFactory Default1.0 mSetting Range24.9 m to -24.9 m (0.1 m steps) Description This is used when cutting r
SPEEDMenu Description SPEED Stored in MemoryYesFactory Default20 cm/sSetting Range1 to 50 cm/s (1 cm/s steps) Description Sets the speed used when cut